BW Icon Multi-Gas Detector, %LEL(IR) O2 H2S CO

SKU: ICON-Y-H

Regular price $340.00

The BW Icon is a fixed-life, 2-year, 4-gas detector for the gas hazards that workers face most often. The Icon is named for its display of simple icons for gas levels and device status. That means no live gas readings for workers to interpret and no time consuming training. Instead, when there’s a gas alarm, the bell icon on the display will illuminate, along with an indicator next to the sensor in alarm, so workers can quickly clear the area.

Features & Benefits:

  • 2 months of battery runtime on a 4.5-hour charge — and up to 4 months if you turn off the detector at the end of each shift. No daily charging, no unexpected downtime
  • No service required, activate and use for two years
  • Bluetooth included for ease of downloading and sending reports via the Safety Suite App
  • Small, lightweight and wearable
  • One-button operation
  • IntelliFlash green light indicates the detector is in compliance; amber light indicates the need for maintenance
  • Compatible with IntelliDoX instrument management system and Honeywell Safety Suite
  • Compatible with TouchConnect, using Bluetooth for wireless configuration

Specifications: 

Size 108.2 mm x 61.5 mm x 43.2 mm (4.29 in x 2.44 in x1.7 in) with Alligator
Clip 108.2 mm x 61.5 mm x 37.8 mm (4.29 in x 2.44 in x 1.49 in) with Klick Fast Stud
Weight 185 g (6.5 oz) with Alligator Clip, 169 g (6 oz) with Klick Fast Stud
Working Temperature -40°C to 60°C (-40°F to 140°F)
Working Humidity 5% to 95%
Ingress Protection IP66, IP68
Alarms and Type Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, Negative Drift, Over Limit, Multi-alarm
Self-Test Perform diagnostic of sensor, circuitry on activation; Activated detector automatically performs analog sensor diagnostic every 10 minutes, digital sensor diagnostic every second
Typical Battery Life Two months (with NDIR CH4 sensor)
Connected Worker Bluetooth® Low Energy (BLE) – Ability to connect to Honeywell's Safety Communicator App, Device Configurator App and Safety Suite Device Configurator Software
User options • Change High, Low, TWA and STEL alarm set points
• Latching alarms
• Set Calibration and/or bump test reminders
• Assign worker and location assignments
• Always on
User options only available via Device Configurator and Safety Suite Device Configurator
Certifications and Approvals ATEX, IEC Ex, contains FCCID, contains IC
Device Warranty Two-year warranty for sensors and detector

 

Sensor Specifications: 

Gas Name
Measuring Range
Resolution
Working Temperature
CO
0 to 2000 ppm
1 ppm
-40°C to 60°C (-40°F to 140°F)
H2S
0 to 200 ppm
1 ppm (can set to 0.1 ppm)
-40°C to 60°C (-40°F to 140°F)
SO2
0 to 150 ppm
0 to 150 ppm
-20°C to 50°C (-4°F to 122°F) intermittent
-40°C to 55°C (-40°F to 131°F)
O2
0 to 30% VOL
0.1% VOL
-40°C to 60°C (-40°F to 140°F)
NDIR-CH4
0 to 100% LEL
1% LEL
-40°C to 60°C (-40°F to 140°F)